Rincian Produk
Tempat asal: Beijing
Nama merek: GOMECY
Sertifikasi: CE
Nomor model: GMS C5 Vertikal
Ketentuan Pembayaran & Pengiriman
Kuantitas min Order: 1
Harga: USD 5299~5899
Kemasan rincian: Kotak aluminium
Waktu pengiriman: 5-7 hari
Syarat-syarat pembayaran: T/T, Western Union, MoneyGram
Menyediakan kemampuan: 500 pcs per bulan
Nama Produk: |
laser pecahan CO2 |
Teknologi: |
Mesin laser CO2 medis |
Fungsi: |
Dermatologi CO2 Laser |
Mode kerja: |
Denyut nadi tunggal, denyut nadi kontinu, denyut nadi berulang |
Tipe laser: |
Tabung Logam |
Panjang gelombang laser: |
10600nm |
Daya output: |
60w |
Daya Input: |
450VA |
Mode operasi: |
Berdenyut, ultra berdenyut, kontinu |
Lebar denyut nadi: |
0,02-0,99S |
Durasi denyut nadi: |
1–100μs |
Pola Pindai: |
Segitiga, persegi, persegi panjang, berlian, garis, bulat |
Divergensi balok: |
4mrad |
Diameter spot terfokus: |
120–240μm |
Bertujuan balok: |
Infrared Ray (630–650nm, <5mw) |
Pengiriman Balok: |
Lengan artikulasi 7-sendi, rotasi 360 ° |
Sistem pendingin: |
Pendinginan sirkulasi internal |
Layar tampilan: |
Layar sentuh LCD warna sejati |
Sistem Operasi: |
Kontrol komputer mikro |
Tegangan input: |
AC220V ± 10%, 50Hz |
Probe: |
Probe Pemindai, Probe Vagina, Probe Bedah |
Nama Produk: |
laser pecahan CO2 |
Teknologi: |
Mesin laser CO2 medis |
Fungsi: |
Dermatologi CO2 Laser |
Mode kerja: |
Denyut nadi tunggal, denyut nadi kontinu, denyut nadi berulang |
Tipe laser: |
Tabung Logam |
Panjang gelombang laser: |
10600nm |
Daya output: |
60w |
Daya Input: |
450VA |
Mode operasi: |
Berdenyut, ultra berdenyut, kontinu |
Lebar denyut nadi: |
0,02-0,99S |
Durasi denyut nadi: |
1–100μs |
Pola Pindai: |
Segitiga, persegi, persegi panjang, berlian, garis, bulat |
Divergensi balok: |
4mrad |
Diameter spot terfokus: |
120–240μm |
Bertujuan balok: |
Infrared Ray (630–650nm, <5mw) |
Pengiriman Balok: |
Lengan artikulasi 7-sendi, rotasi 360 ° |
Sistem pendingin: |
Pendinginan sirkulasi internal |
Layar tampilan: |
Layar sentuh LCD warna sejati |
Sistem Operasi: |
Kontrol komputer mikro |
Tegangan input: |
AC220V ± 10%, 50Hz |
Probe: |
Probe Pemindai, Probe Vagina, Probe Bedah |
The CO₂ laser is a high-energy system that emits light at a wavelength of 10600nm, which is strongly absorbed by water in biological tissues. Because human skin and mucosa are rich in water, this laser is highly effective in cutting, vaporizing, and coagulating soft tissue with excellent precision.
The device uses fractional scanning technology and different probes to adapt to dermatology, gynecology, and surgical procedures.
In dermatology, the fractional CO₂ laser creates microthermal zones in the skin, stimulating collagen regeneration and improving skin texture, wrinkles, scars, and pigmentation.
In gynecology, the CO₂ vaginal probe promotes mucosal regeneration, improves tissue elasticity, and restores vaginal health.
In surgery, the precise cutting ability allows minimally invasive operations with reduced bleeding and faster healing.
This combination of applications makes it a versatile solution for clinical and cosmetic needs.
Skin resurfacing and rejuvenation
Reduction of fine lines and wrinkles
Scar improvement (acne scars, surgical scars, burn scars)
Pigmentation treatment
Skin tightening and pore reduction
Vaginal tightening and rejuvenation
Improvement of dryness and laxity
Postpartum tissue restoration
Supportive therapy for mild incontinence
Cutting and vaporization of soft tissue
Coagulation to reduce bleeding
Precise excision with minimal damage to surrounding tissue
Parameter | Specification |
---|---|
Working Mode | Single pulse, Continuous pulse, Repeated pulse |
Laser Type | Metal Tube |
Laser Wavelength | 10600nm |
Output Power | 60W |
Input Power | 450VA |
Operation Modes | Pulsed, Ultra Pulsed, Continuous |
Pulse Width | 0.02–0.99s |
Pulse Duration | 1–100μs |
Scan Patterns | Triangle, Square, Rectangle, Diamond, Line, Round |
Beam Divergence | 4mrad |
Focused Spot Diameter | 120–240μm |
Aiming Beam | Infrared Ray (630–650nm, <5mW) |
Beam Delivery | 7-joint articulated arm, 360° rotation |
Cooling System | Internal circulation cooling |
Display Screen | True color LCD touch screen |
Operation System | Microcomputer control |
Input Voltage | AC220V ±10%, 50Hz |
Probes | Scanner probe, Vaginal probe, Surgical probe |
Versatile Probes: Equipped with scanner, gynecological, and surgical handpieces.
Fractional Scanning: Adjustable scan patterns and spot sizes for tailored treatments.
Precision Cutting: Ultra-pulsed mode for delicate surgical applications.
Smart Control System: Microcomputer-based, user-friendly interface.
Efficient Cooling: Built-in circulation ensures stable performance.
Ergonomic Design: 7-joint articulated arm provides flexibility and accuracy.
Cleanse the treatment area.
Apply topical anesthesia if needed.
Select scan pattern, energy level, and pulse duration.
Deliver fractional CO₂ laser to target area.
Apply cooling gel or soothing mask after treatment.
Gynecological evaluation and patient preparation.
Apply local anesthesia or numbing gel if required.
Insert vaginal probe gently.
Deliver laser energy in fractional mode for mucosal stimulation.
Patient may resume normal activity within 1–2 days.
Prepare surgical site under aseptic conditions.
Adjust laser mode (pulsed, continuous, or ultra-pulsed).
Perform incision, vaporization, or coagulation as needed.
Minimal bleeding due to coagulation effect.
Postoperative dressing and care.
Avoid sun exposure and tanning for at least 2 weeks before treatment.
Do not use retinoids or exfoliating agents 1 week prior.
Inform the doctor about any medications or medical history.
For gynecology, ensure no active infection or menstruation period.
Apply prescribed soothing ointments to the treated area.
Avoid hot baths, sauna, and strenuous exercise for 1 week.
Keep the treated skin clean and moisturized.
Use sunscreen daily to prevent pigmentation.
For gynecological procedures, avoid activity for 5–7 days.
Pregnancy and breastfeeding
Severe systemic diseases (uncontrolled diabetes, cardiovascular conditions)
Active infections or open wounds at the treatment site
History of keloid formation or abnormal scarring
Blood clotting disorders or use of anticoagulants